top of page

The swivel tester is used for evaluating the ability of the chair to withstand stresses and wear of repeated swiveling. During the test, the base of chair needs to be restrained on machine’s rotating table and keep the seat and backrest restrained so as to affect the base rotation.

Then load the mass of 122kg (270lb) on the seat in loading point, rotate the chair at a rate between 5 and 15 rotations per minute and with a rotation of 0°-360° total for 120,000 cycles

Chair Swivel Durability Tester

    • EN 1728 Clause 7.11 
    • EN 1728 Clause 7.13
    • BIFMA X5.1 Clause 8
  • Machine Dimension (W*D*H)

    1200*1000*2320mm

    Machine weight

    About 250kg

    Max. sample size

    5-castor chair with Φ750mm

    Chair Seat height

    350-800mm

    Frame Work

    #4080 of aluminum profile

    Display System

    PLC with touch screen

    Air Source

    0.7Mpa

    Power

    220V, 50-60Hz can be adjusted